A Fluorescence-Based Wireless Capsule Endoscopy System for Detecting Colorectal Cancer
The proof of concept of this endoscopic capsule was tested on porcine intestine and liquid phantom. The proposed WCE system offers great possibilities for future applicability in selective and specific detection of other fluorescently labelled cancers.
Mohammad Wajih Alam
,
Seyed Shahim Vedaei
,
Khan A Wahid
PDF
Cite
DOI
An Chapter 1 - IoT-Based Intelligent Capsule Endoscopy System - A Technical Review
This chapter presents a review on the wireless capsule endoscopy (WCE) system and proposes a list of new features that are desired in the next generation Internet of Things (IoT)-based WCE system.
Mohammad Wajih Alam
,
Md Hanif Ali Sohag
,
Alimul H. Khan
,
Tanin Sultana
,
Khan A. Wahid
PDF
DOI
Single channel high noise level ECG deconvolution using optimized blind adaptive filtering and fixed-point convolution kernel compensation
The results demonstrate that the proposed algorithm renders a much-improved performance in removing the noise from ECG signals, especially in a scenario where signal to noise ratio is negative. Moreover, the noninvasive fetal ECG dataset (NI-FECG) provided by Physionet is also used for fetal ECG extraction by a single thoracic channel. By comparing fetal ECG extraction methods in the literature and the proposed method, it reveals that the proposed method can extract the QRS complex of fetal ECG by a single thoracic channel as accurate as other methods which use abdominal channels.
Mohammad Reza Mohebbian
,
Mohammad Wajih Alam
,
Khan A. Wahid
,
Anh Dinh
PDF
Cite
DOI
Development of a low-cost and portable smart fluorometer for detecting breast cancer cells
We demonstrate that the developed fluorometer is able to distinguish between the cancer cell expressing GFP and the control cell. The fluorometer we developed exhibits immense potential for future applicability in the selective detection of fluorescently-labelled breast cancer cells.
Mohammad Wajih Alam
,
Khan A Wahid
,
Raghuveera Kumar Goel
,
Kiven Erique Lukong
PDF
Cite
DOI
A Low-Cost and Portable Smart Instrumentation for Detecting Colorectal Cancer Cells
A near-infrared fluorescent protein IRFP702 was expressed in the colorectal cancer cells that were used to test the proof-of-concept. The fluorescent cancer cells were first tested with a commercial imaging system (Odyssey® CLx) and then with the developed prototype to validate the result in a preclinical setting. The developed fluorimeter is versatile as it can also be used to detect multiple types of cancer cells by simply replacing the filters based on the fluorophore.
Mohammad Wajih Alam
,
Khan A Wahid
,
Fahmid Islam
,
Wendy Bernhard
,
Clarence R Geyer
,
Franco J Vizeacoumar
PDF
Cite
DOI
Reliability Analysis of Io VT Based Intelligent Video Surveillance System
This paper proposes a different framework to analyze the system via the concept of reliability. The existing approaches depend solely upon the system input sequences. However, the proposed framework works on the component statistical index. Based on exponential distribution theory of reliability, the reliability of the intelligent VSS is analyzed in this paper, followed by a complete guideline to improve the current reliability of the system
Tanin Sultana
,
Mohammad Wajih Alam
,
Khan Wahid
Cite
DOI
Is there an application for wireless capsule endoscopy in horses?
This pilot study assessed wireless capsule endoscopy in horses. Image transmission was achieved with good image quality. Time to exit the stomach was variable and identified as one limitation, together with gaps in image transmission, capsule tumbling, and inability to accurately locate the capsule. Findings demonstrate usefulness and current limitations.
Julia B Montgomery
,
Jose L Bracamonte
,
Mohammad Wajih Alam
,
Alimul H Khan
,
Shahed K Mohammed
,
Khan A Wahid
PDF
Cite
DOI
Are Current Advances of Compression Algorithms for Capsule Endoscopy Enough? A Technical Review
In this review, we aim to address the issue by exploring the characteristics of endoscopic images, analyzing the strengths and weaknesses of useful compression techniques, and making suggestions for possible future adaptation.
Mohammad Wajih Alam
,
Md Mehedi Hasan
,
Shahed Khan Mohammed
,
Farah Deeba
,
Khan A Wahid
PDF
Cite
DOI
A Low-Cost Digital Microscope with Real-Time Fluorescent Imaging Capability
This paper describes the development of a prototype of a low-cost digital fluorescent microscope built from commercial off-the-shelf (COTS) components. The prototype was tested to detect malignant tumor cells taken from a living organism in a preclinical setting.
Md Mehedi Hasan
,
Mohammad Wajih Alam
,
Khan A Wahid
,
Sayem Miah
,
Kiven Erique
PDF
Cite
DOI
A Novel Design of Feeder System for Aqua Culture Suitable for Shrimp Farming
Shrimp farming is one of the most important aqua cultural activities, but farmers are facing many serious problems like shrimp diseases partly due to problems with the shrimp having to cope with poor water quality during cultivation.
Dileep Kumar Appana
,
Mohammad Wajih Alam
,
Bigyan Basnet
PDF
Cite
DOI
Optimum Arrangement and Combination of Receive only and Transmit Only Coils for Imaging at 7 Tesla
In MRI, surface coil has an advantage of providing increased signal to noise ratio. In this research, the advantage of surface coils and transmit coils is utilized by combining a varying number of receive only surface coil with 8 channel transmit only TEM coil for imaging brain at 7 T.
Mohammad Wajih Alam
,
Youngdae Cho
,
Hyoungsuk Yoo
Cite
Transmit Receive RF Resonator Optimization at 7 T MRI System
A 7 Tesla 32-channel close fitting helmet shaped phased-array surface coils along with the combination of 8 channel transmit only transverse electromagnetic coils provided good homogeneity as well as significant SNR improvements throughout the human brain.
Mohammad Wajih Alam
,
Hyoungsuk Yoo
PDF
Cite
DOI
A Heartbeat and Temperature Measuring System for Remote Health Monitoring using Wireless Body Area Network
This paper presents the design and development of a microcontroller based heartbeat and body temperature monitor using fingertip and temperature sensor. The device uses the optical technology to detect the flow of blood through the finger and offers the advantage of portability over conventional recording systems.
Mohammad Wajih Alam
,
Tanin Sultana
,
Mohammad Sami Alam
PDF
Cite
DOI
Optimum number of receive only surface coil optimized for Imaging Brain at 7T
Magnetic Resonance Imaging (MRI) has a potential to increase signal-to-noise ratio in order to produce clear anatomical as well as functional images of human. Different types of coil has different kind of advantage. TEM coil has an ability to produce homogeneous B1 field but with low SNR while surface coil has a capability of providing us with increased SNR. This paper makes the use of increasing number of receive only surface coil arrays (in varying number) in order to increase SNR.
Mohammad Wajih Alam
,
Youngdae Cho
,
Hyoungsuk Yoo
Cite
MODELING AND CONTROLLING OF AN ELECTRO-HYDRAULIC ACTUATOR NOVEL BY USING INDEPENDENT METERING VALVE
This paper presents the structure and dynamic of a new hydraulic cylinder circuit using independent metering valves combine with control variable displacement pump to saving energy. This hydraulic circuit is simulated and compared with conventional by AMESim and Matlab Software.
Debdatta Das
,
Mohammad Wajih Alam
,
S.M. Rifat Iftekhar
Cite
EFFECTIVE ARRANGEMENT OF OPTIMUM NUMBER OF TEM COILS FOR THE IMPROVEMENT OF B1 FIELD HOMOGENEITY AROUND THE HEAD OF HUMAN PHANTOM AT 7 TESLA
In this paper, the performance of different coil is compared based on number of channel and the generation of homogeneous B1 field in the head. The number of channel (4, 6, 8, 10 and 12) of Tx/Rx coil will be varied in order to compare SNR, signal intensity (SI) and B1 field homogeneity utilizing B1 mapping sequence.
Mohammad Wajih Alam
,
Tanin Sultana
,
Debdatta Das
,
Mohammad Sami Alam
,
Dhiman Kumar Sarker
Cite
AN APPLICATION OF NEURO - FUZZY ADAPTIVE PID CONTROLLER A DIRECT DIVE VOLUME CONTROL HYDRAULIC PRESS
This paper presents a Neuron Fuzzy Adaptive PID controller for the development of high Position control precision in the hydraulic press machines.
Debdatta Das
,
Puja Chowdhury
,
Mohammad Wajih Alam
,
S.M. Rifat Iftekhar
Cite
A STUDY ON AN ENERGY SAVING METHOD OF BOOM CYLINDER IN ELECTRO-HYDRAULIC EXCAVATOR
This paper presents a new energy saving electro-hydraulic circuit design for the energy regeneration. In this system, a power storage component and an electrical battery is combined with an electro-hydraulic actuator using a hydraulic motor and an electric generator as energy convention component.
Debdatta Das
,
Puja Chowdhury
,
Mohammad Wajih Alam
,
S.M. Rifat Iftekhar
,
Jamal Uddin Ahamed
Cite
A wireless heartbeat and Temperature Monitoring System for Remote Patients
This paper describes the development of a wireless heartbeat and temperature monitoring system based on a microcontroller at a reasonable cost with great effect.
Mohammad Wajih Alam
,
Choton Kanti Das
,
Imran Hoque
Cite
DOI
Reliability Analysis of Io VT Based Intelligent Video Surveillance System
This paper presents the design and development of a RFID based Room Automation using microcontroller. This paper has shown the concept of an automatic Door Access System with Automatic Room Light Controller and Visitor Counter. The concept of access control is brought about using a card, a corresponding card reader and a control panel.
Mohammad Sami Alam
,
Mohammad Wajih Alam
,
Tanin Sultana
Cite
DOI
Cite
×